Is your solar system working properly? How to check it
Your inverter app shows a number every day, but is it the right number? A lot of systems went up in a hurry during load-shedding, and some were never checked against what the roof can actually deliver. You can check yours in about 15 minutes, as long as you know roughly how it's put together.
Explore the sample projectOpens the designer with a worked example of a home system. Free, no account needed.
What you need
- Your inverter app (Sunsynk Connect, SolarMan, Victron VRM or similar), with at least a few months of history. A year is better.
- The panel model, from the label on the back of a panel, the installer's quote or the certificate of compliance paperwork. You need its watts and its working voltage (Vmp) from the datasheet.
- How many panels, and which way each group faces.
- The inverter and battery models, from the units themselves or the app.
Work out how the panels are wired
Panels are wired in strings: several in series, each string going to one inverter input. Most hybrid inverter apps show each input's voltage, often as PV1 and PV2. That voltage tells you how many panels are in the string.
panels in series ≈ PV input voltage ÷ panel working voltage (Vmp)
Say PV1 reads 330 V around midday and the panel's datasheet gives a Vmp of 41.6 V. That's 330 ÷ 41.6 = 7.9, so 8 panels. Hot panels run at a lower voltage than the datasheet figure, so on a hot afternoon the same string might read 300 V and work out at 7.2. Round up, then check it against the number of panels you can count on the roof. If both inputs have panels, do the same for PV2.
Draw it in Lekker Sun
- Open the designer, find your house on the satellite map and set the location.
- Draw the house with its roof shape, pitch and the way each roof face points. Add trees, chimneys and neighbouring buildings that throw shade on the roof.
- Place the panels as they are installed, on the right roof faces.
- Add your panel and inverter models. Many common models are in the equipment library; if yours isn't, type in its datasheet values. Then switch on Strings and give each panel the inverter input (MPPT 1 or 2) it's wired to, the way you worked out above.
- Run the simulation. You'll see the expected production for each month and for the year, and how much the shading costs.
The compatibility checks also run for free. If one fails, for example the string voltage on a cold morning is above the inverter's limit, that's worth raising with your installer: it can damage the inverter or void its warranty. String voltage in cold weather explains why.
Compare month by month
Put the app's monthly production next to Lekker Sun's expected production. Compare months, not days. One cloudy week can drag a month down, and the simulation uses a typical weather year for your area, not this year's actual weather. A single month 15 to 20 % below expected can just be weather. A shortfall that keeps showing up over several sunny months is the one to look at.
The free simulation shows the production potential: what the panels can make if every kWh is used. Keep that in mind for the next part.
What a gap usually means
- Lower mainly in sunny months, and the battery is full by midday. Usually your system doesn't feed into the grid (zero export). Once the house load is covered and the battery is full, the inverter throttles the panels back and that solar is lost. The app shows less, but nothing is broken. The system may simply be bigger than you can use.
- One input much lower than another with similar panels. Something is shading that string, or there's a fault such as a loose connection, a failed panel or a blown fuse. An input at zero on a sunny day needs your installer.
- Lower across every month. Check the drawing first: roof pitch, facing and the panel model. If those are right, look for shading you haven't drawn (trees grow), dirty panels, or a fault.
- Production flat-topped at midday. The panels can make more than the inverter can handle, so it clips the peak. Usually a small loss. See DC/AC ratio and clipping.
- Higher than expected. Usually the drawing understates the roof (wrong pitch or facing), or it's been a sunny year.
Is it saving what you were promised?
Production is half the story. The other half is how much of it you use and what it saves on your bill. With a saved project, Lekker Sun simulates your battery and household usage through a typical year, estimates how much zero export throws away, and shows your electricity bill with and without solar on your tariff, with the payback. If your installer gave you a payback figure, this is where you can check it.
Before you call your installer
Lekker Sun's figures are estimates from a model of your roof, not measurements. Go back to your installer with the specifics: which months were low, by how much, which input, and what you've already checked. Most installers would rather fix a problem than lose a customer, and a clear, fair question gets a better answer than an accusation.
Check your own system
The designer's free and runs in your browser. You don't need an account.
This guide is general information to help you understand your system. It is not engineering, electrical or financial advice. Results from Lekker Sun are estimates. Don't open the inverter, isolators or wiring yourself: have a qualified, registered installer inspect any fault.